Description: Returns the value of the acceleration factor. Only available for stress-dependent models. Time required only for a Cumulative Damage model with time-dependent stresses.
Field Format: [ACCELERATIONFACTOR(Source Number)(Time;Accel Stress 1;Accel Stress 2;Accel Stress 3;Accel Stress 4;Accel Stress 5;Accel Stress 6;Accel Stress 7;Accel Stress 8)]
Source Number is the associated data source number.
Time is the time at which the acceleration factor is calculated. This is required only when the source data sheet uses the Cumulative Damage model with time-dependent stresses.
Accel Stress values are the acceleration stress levels for each stress type. The number of stress inputs is determined by the number of stress types in the specified data source.
Remarks:
The Source Number is selected from the Data Source Index drop-down list.
The Time value must be greater than or equal to 0.
The Accel Stress values must be greater than 0.
Example:
[ACCELERATIONFACTOR(1)(0;315;;;;;;;)]
© 1992-2016. ReliaSoft Corporation. ALL RIGHTS RESERVED.
![]() |
E-mail Link |