Related Topics:

Contained Load Sharing Blocks

Reliability Block Diagrams (RBDs)

Block Properties

Load Sharing Containers

Load sharing containers allow you to identify blocks that are in load sharing redundancy. This indicates that two or more blocks in the container share the responsibility for keeping the system running properly; if one of them fails, the other(s) can take on an increased “load” so the system can continue to operate. Therefore, load sharing components exhibit different failure characteristics when one or more fail.

For example, suppose that two heat dissipation devices operate in a load sharing configuration and together they are expected to provide dissipation for a temperature difference of 100 K of heat. When both units are operating, they share the load and each dissipates 50% of the heat. If one unit fails, then the load on the other unit is increased to 100% of the heat.

In the figure shown next, Blocks 1, 2 and 3 are in a load sharing container and have their own failure characteristics. If the container’s properties specify that only one contained block must succeed in order for the container to succeed, then all three contained blocks must fail for the container to fail. However, as individual contained blocks fail, the failure characteristics of the remaining contained blocks change because they now have to carry a higher load to compensate for the failed ones.

The container has properties that describe the way the container behaves. A block inside a container, a contained block, also has its own block properties.

To configure a load sharing container, in addition to the common block properties, you will need to specify the Number of Paths Required, which is the number of active blocks/paths within the container that must succeed in order for the container to succeed. If the required number of blocks/paths does not succeed, then the container is considered to be failed. The contained blocks must be within the load sharing container, but they do not need to be connected to each other.

Additional options are available for the load sharing container, including:

When this option is selected, no other properties will be available for the block; note, however, that any properties you have already specified are simply hidden because they are not relevant. The settings will reappear if you clear the Set block as failed option.

For load sharing containers in simulation diagrams, you can also specify throughput properties, which define the amount of output that can be processed by the block in a given period of time.

The ReliaWiki resource portal has more information on load sharing configurations at: http://www.ReliaWiki.org/index.php/Time-Dependent_System_Reliability_(Analytical).

 