Description: Returns the specified system-level simulation result (Result ID).
Field Format: [SIM_SYSTEM_RESULTS(Source Number)(Result ID)]
Source Number is the associated data source number.
Result ID is the specific piece of data you are retrieving. The Result ID can be of the following values:
| # | Result ID | # | Result ID | |
| 0 | Simulation End Time | 20 | Number of OFF Events | |
| 1 | Mean Availability | 21 | Throughput | |
| 2 | Mean Availability Std Deviation | 22 | CM Misc Cost | |
| 3 | Mean Availability (w/o PM & Inspection) | 23 | CM Pool Cost | |
| 4 | Expected Number of Failures | 24 | CM Crew Cost | |
| 5 | Expected Number of Failures Standard Deviation | 25 | CM Total Cost | |
| 6 | MTTF | 26 | PM Misc Cost | |
| 7 | Uptime | 27 | PM Pool Cost | |
| 8 | Downtime | 28 | PM Costs for Crews | |
| 9 | CM Downtime | 29 | PM Total Cost | |
| 10 | Failure Downtime | 30 | OC Misc Cost | |
| 11 | Inspection Downtime | 31 | OC Pool Cost | |
| 12 | PM Downtime | 32 | OC Costs for Crews | |
| 13 | OC Downtime | 33 | OC Total Cost | |
| 14 | OFF Event Downtime | 34 | IN Misc Cost | |
| 15 | Number of Failures | 35 | IN Crew Cost | |
| 16 | Number of CMs | 36 | Indirect Pool Cost | |
| 17 | Number of Inspections | 37 | Downtime Cost | |
| 18 | Number of PMs | 38 | Total Cost | |
| 19 | Number of OCs | |||
Remarks:
The Source Number must be either 1, 2, 3 or 4.
Example:
[SIM_SYSTEM_RESULTS(1)(4)]
Returns:
10.499 [This is the expected number of failures for the system for data source 1 at the end of the simulation.]
Note that this value will vary depending on the source diagram.